Serchem are now offering a brand new range of Protein Detection technology. 

miniPro Device

Auto-Reader for Residual Protein Detection System

MiniPro Devices together

The miniPro Device is used for the incubation and quantitative readout of the pen system for the detection of proteins and surface allergens. It designed under Quality Management Systems Standards 13485:2003/NS-EN ISO 13485:2012. Some of the characteristics include;-

  • Orifice for external thermometer.
  • Built-in top cover USB connection for recording results on PC using a Readout and Traceability software.
  • It allows to incubate and read 3 indicators simultaneously.
  • Thermal Printer results. Sound alarm for indication of events.

The miniPro has a button for each reading position that allows the selection of the program and starting it. It also has an automatic readout system and a printer to record the data. In addition, it has a button for the reprint of the last 3 results and for the verification of the remaining incubation time. Please contact Serchem for further information on this.

PRO1MICRO: 15 min. at 60ºC.

https://www.youtube.com/watch?v=MhFmDF-Q19Y

  • Code
    MINIPRO

PRO1 MICRO

Protein Detection Pen Swab

PRO1MICRO

The PRO1 MICRO Hygiene Monitoring System has been designed to detect proteins and to reduce iatrogenic agents on surgical instruments after cleaning them in real time. The system has a high absorption swab that allows of samples from different surfaces with high efficiency. A visual readout of a colour change indicates the presence of detectable levels of protein. The PRO1 MICRO system has been designed to detect proteins, allergens and reducing agents on surfaces after the cleaning process and in areas of difficult access.

  • Code
    PR01MICRO

CDWA3 / CDWA4

Cleaning Indicators

CDWA4

Cleaning Indicators for thermodisinfection machines consist of a synthetic support of 70 x 30mm, which is stable at disinfection temperatures. Each indicator contains a mixture of specially combined coloured organic components. The CDWA Indicators formulation allows detection of all factors that affect the cleaning process outcome. CDWA indicators can be used for routine monitoring of cleaning processes in automatic machines with different washing and thermodisinfection configurations.

CDWA cleaning system offers two different levels of cleaning with different wash-off characteristics, thus allowing different challenge levels to test cleaning efficiency.

CDWA are validated according to testing samples described in ISO/TS 15883 Part 5.

  • Code
    CDWA3 / CDWA4

CDWAH

Cleaning Indicator Holder

CDWAH

CDWAH has been designed to hold CDWA Cleaning Indicators, used for cleaning process routine control and monitoring of automatic washing machines effectiveness as well as monitoring ultrasonic washers. The holder can be fixed on the tray, which allows reproducible location of the cleaning indicator in the washer-disinfector.  When a CDWA cleaning indicator is placed within the holder, half of the test soil is covered, thus simulating the joint of a surgical instrument, with water steam hitting it indirectly. The other half of the test soil is covered by a mesh, thus posing a challenge for water to reach it, emulating shadowed or occluded surfaces.

  • Code
    CDWAH

KPRO2-E69 / KPR02-E250

Protein Swabs

KPRO2 E250 KPRO2 E69

KPRO2-E69 and KPRO2-E250 Hygiene Monitoring Systems have been designed to test cleanliness of surgical equipment by detecting protein residues left behind following improper cleaning. The systems have a high absorption swab, allowing the collection of samples from different surfaces with the same efficiency. These are compatible with cleaning verification of endoscopes and other reusable instruments with hard-to-reach internal channels or cannulated instruments. They can be used on washer-disinfectors, ultrasonic cleaners, surgical instruments and endoscopes.

  • Code
    KPRO2-E69 / KPR02-E250

CCDER1 / CCDER2

Endoscopy PCD Holder

CCDER122

CDDER1 & CDDER2 devices consist of a perforated plastic capsule able to hold the CDWE cleaning indicator, which contains a mixture of specially combined coloured components. The capsule is connected to a high resistance plastic tube of 2 meters long and mm (CCDER1) or 2mm (CDDER2) internal diameter. In addition, the tube has luer-lock connector, which enables the connection to Automatic Endoscope Reprocessor terminals. One luer-lock male and female terminal are included. You may choose the most appropriate terminal for your AER.

  • Code
    CCDER1 / CCDER2

CCDER122

Endoscopy PCD Holder

CCDER122 KIT

CDER11 Device consists of three perforated plastic capsules, which can hold the CDWE cleaning indicator and are connected to 2-meter long high resistance plastic tubes. One of the tubes has 1mm of internal diameter and the other two have 2mm of internal diameter. Furthermore, each tube has a luer-lock connector that enables the connection to Automatic Endoscope Reprocessor terminals. One luer-lock male and female are included for each tube. You can choose the most appropriate terminal for your AER.

  • Code
    CCDER122

CDWE

Cleaning Indicator

CDWE

CDWE Cleaning Indicator consists of a 38mm x 6mm synthetic, adhesive and temperature-stable support printed with indicating coloured ink. CDWE allows detection of failures of all factors affecting the outcome of the cleaning process of endoscopes in Automatic Endoscope Reprocessors. The indicator ink is non-toxic.

  • Code
    CDWE